Elecon - Electrical cables and conductors for all kind of industrial uses.

Elecon - Electrical cables and conductors for all kind of industrial uses.

Flexible instrumentation and control cable, shielded pairs formed together with copper braid.

For applications that require extra protection against electrical noise and crosstalk.


Flame retardant, No propagador de la llamaRoHS COMPLIANT, Conforme con la RoHS, Restricción de Sustancias Peligrosas en aparatos eléctricos y electrónicosEuropean ConformityQuality Certification. UNE-EN ISO 9001 / AENOR ER-0298/2002IQNet Certified

1. Conductor
Bare Flexible copper according to UNE-EN 60228

2. Insulation
PVC type TI2 according to EN-50363-3

3. Wiring
In pairs (same numbers)

4. Wiring
In concentric layers

5. Shield on pairs
Polyester tape + Braid tinned copper (60%)

6. Outer jacket
PVC outer sheath TM2 according to EN-50363-4-1
 Color Black or Blue

Rated voltage: 300/500 V

Test voltage: 2.000 V

 

Temperature Range

From: -15 ºC to 70 ºC

Bending radius:

10 times the diameter ext. cable (mm)

Flexible instrumentation and control cable, shielded pairs formed together with copper braid. Suitable for applications requiring protection against electrical noise and high crosstalk.

No flame propagation:
UNE-EN 50265-2-1 (IEC 60332-1)

Color code (UNE 21089-1:2002 / HD 308 S2 2001)


Nº of conductors
  • White
  • Green
  • Grey
  • Blue
  • Black
  • Grey / Pink
  • White / Green
  • White / Yellow
  • White / Grey
  • White / Pink
  • White Blue
  • White Red
  • White / Black
  • Grey / Green
  • Pink / Green
  • Green Blue
  • Green / Red
  • Green / Black
  • Gray / Blue
  • Grey / Red
  • Grey / Black
  • Blue / Black
Isolation Color
  • Brown
  • Yellow
  • Rose
  • Red
  • Purple
  • Red Blue
  • Brown / Green
  • Yellow / Brown
  • Grey / Brown
  • Pink / Brown
  • Brown / Blue
  • Brown / Red
  • Brown / Black
  • Yellow / Gray
  • Yellow / Pink
  • Yellow Blue
  • Yellow Red
  • Yellow / Black
  • Blue Rose
  • Pink / Red
  • Pink / Black
  • Red / Black


NxS / NGS (mm2)
  • 2x2x0.75
  • 3x2x0.75
  • 4x2x0.75
  • 6x2x0.75
  • 7x2x0.75
  • 10x2x0.75
  • 12x2x0.75
  • 16x2x0.75
  • 20x2x0.75
  • 2x2x1
  • 3x2x1
  • 4x2x1
  • 6x2x1
  • 7x2x1
  • 10x2x1
  • 12x2x1
  • 16x2x1
  • 20x2x1
  • 2x2x1.5
  • 3x2x1.5
  • 4x2x1.5
  • 6x2x1.5
  • 7x2x1.5
  • 10x2x1.5
  • 12x2x1.5
  • 16x2x1.5
  • 20x2x1.5
  • 2x2x2.5
  • 3x2x2.5
  • 4x2x2.5
  • 6x2x2.5
  • 8x2x2.5
  • 10x2x2.5
  • 12x2x2.5
  • 16x2x2.5
  • 20x2x2.5
∅ exterior (mm nom.)
  • 10
  • 10.7
  • 11.8
  • 14.3
  • 14.3
  • 18.6
  • 19.2
  • 21.5
  • 24.1
  • 10.8
  • 11.5
  • 12.7
  • 15.4
  • 15.4
  • 20
  • 20.7
  • 23.3
  • 26.1
  • 12.6
  • 13.5
  • 14.9
  • 18.2
  • 18.2
  • 23.8
  • 24.6
  • 27.6
  • 31
  • 14.7
  • 15.6
  • 17.4
  • 21.2
  • 21.2
  • 27.8
  • 28.8
  • 32.4
  • 35.4
Strength Ω/km a 20 °C
  • 26
  • 26
  • 26
  • 26
  • 26
  • 26
  • 26
  • 26
  • 26
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 19.5
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 13.3
  • 7.98
  • 7.98
  • 7.98
  • 7.98
  • 7.98
  • 7.98
  • 7.98
  • 7.98
  • 7.98
capacity* (C-C) pF/m
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 170 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 180 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%
  • 200 ± 20%


(*) Capacity between conductors (value approx.)

Top