Elecon - Electrical cables and conductors for all kind of industrial uses.

Elecon - Electrical cables and conductors for all kind of industrial uses.

Power cable suitable for the precision servo control.

Designed for use in power chains, handling automation, robots, machine tools and processing machines and machining. Equipped with protective screen against electromagnetic interference (EMC).


Flame retardant, No propagador de la llamaRoHS COMPLIANT, Conforme con la RoHS, Restricción de Sustancias Peligrosas en aparatos eléctricos y electrónicosCSA StandardDESINA Standard, DistributEd and Standardised INstAllation technologyEuropean ConformityQuality Certification. UNE-EN ISO 9001 / AENOR ER-0298/2002IQNet Certified

According to: UL Style 21223

1. Conductor

Extra flexible copper Cl. 6 according to UNE-EN 60228 / VDE 295

2. Insulation

Polyolefin according to UL Style 21223

3. Independent wiring

Control wiring conductors pairs

4. Independent Shield

Polyester tape +  Braid Tinned Copper

5. General wiring

Control Cable + power conductors wiring each other

6. General Shield

Polyester tape + Braid Tinned Copper , 85% coverage

7. Outer jacket

Polyurethane resistant to abrasion and chemical agents, UV VDE 472-803 / B - 2110 HD
Orange (RAL 2003)

Rated voltage: 300 V

Test voltage: 2.000 V

Temperature Range

Mobile Service: -40 ºC to 80 ºC

Fixed Service: -40 ºC to 80 ºC

Bending radius:

7.5 times the diameter ext. cable (mm) in flexion

6 times the diameter ext. cable (mm) fixed

Power cable suitable for the precision servo control. The cables have been specially designed for use in power chains, handling automation, robots, machine tools and processing machines and machining. The materials used guarantee resistance to mineral oils, greases, coolants and hydraulic fluids. Low capacity cables equipped with protective shield against electromagnetic interference (EMC). Polyurethane cover to increase resistance to abrasion and weathering.

Flame propagation:
UNE-EN 50265-2-1 (IEC 60332-1)

Mineral Oil Resistent:
VDE 282-10 y HD 20-10

Halogen free:
UNE-EN 50267-2-1 / IEC 60754-1

Hydrolysis resistant:
HD 20-10

UV Resistent

Color code (UNE 21089-1:2002 / HD 308 S2 2001)


Nº of conductors
Isolation Color


NxS / NGS (mm2)
  • 4G1,50+(2x1.5)
  • 4G2,50+(2x1.5)
  • 4G4+(2x1.5)
  • 4G6+(2x1.5)
  • 4G10+(2x1.5)
  • 4G16+(2x1.5)
  • 4G25+(2x1.5)
  • 4G35+(2x1.5)
  • 4G50+(2x1.5)
  • 4G1,50+2x(2x0.75)
  • 4G2,50+2x(2x0.75)
  • 4G4+(2x1)+(2x1.5)
  • 4G6+(2x1)+(2x1.5)
  • 4G10+(2x1)+(2x1.5)
  • 4G16+2 (2x1.5)
  • 4G25+2 (2x1.5)
  • 4G35+2 (2x1.5)
∅ exterior (mm nom.)
  • 11.6
  • 12.8
  • 13.9
  • 16.2
  • 19.7
  • 24.2
  • 28.5
  • 32.4
  • 37.5
  • 13
  • 14.2
  • 16.3
  • 18.3
  • 22.3
  • 26.8
  • 29.3
  • 32.4
Strength Ω/km a 20 °C
  • 13,3
  • 7,98/13.30
  • 4,95/13.30
  • 3,30/13.30
  • 1,91/13.30
  • 1,21/13.30
  • 0,78/13.30
  • 0,554/13.30
  • 0,386/13.30
  • 13,30/26
  • 7,98/26
  • 4,95/19.5/13.30
  • 3,30/19.5/13.30
  • 1,91/19.5/13.30
  • 1,21/13.30
  • 0,78/13.30
  • 0,554/13.30
Intensity A (25 °C)
  • 28
  • 40
  • 52
  • 66
  • 88
  • 115
  • 150
  • 180
  • 215
  • 28
  • 40
  • 52
  • 66
  • 88
  • 115
  • 150
  • 180



Top